Product Description:
1. Equipments Details / Features :1.0 Charge/Discharge Channels : 22 nos Bitrode make• Voltage...Product Description:
1. Equipments Details / Features :
1.0 Charge/Discharge Channels : 22 nos Bitrode make
• Voltage 0 - 18 Volts with accuracy 0.1%
• Current 0 - 25 amps 14 channels, 0 -50 amps 6 channels, 0 - 100 amps 2 Channels with accuracy 0.1%
• Temperature 0 -200 degree with accuracy 1%
• Programmable up 100 segments
• Use:- to charge and discharge battery for conducting capacity, life and overcharge endurance tests.
2.0 High Rate Dischage Tester : 1 no Bitrode make
•Voltage 0 - 18 Volts with accuracy 0.1%
• Current 0 - 1500 amps with 0.1 % accuracy and 1 amp resolution
• Cut off voltage 0 V up to 1000 amps and 2.7 V from 1000 amps to 1500 amps.
• Temperature 0 -200 degree with accuracy 1%
• Programmable up 100 segments
• Use:- To carry out high Rate discharge Test i.e. Cranking Test
3.0 High Rate Charge/Discharge Tester : 1 no. Bitrode make
• Voltage 0 - 48 Volts with accuracy 0.1%
• Current 0 - 1000 amps with 0.1 % accuracy and 1 amp resolution
• Cut off voltage 0 V up to 1000 amps and 2.7 V from 1000 amps to 1500 amps.
• Temperature 0 -200 degree with accuracy 1%
• Programmable up 100 segments
• Use:- To carry out High Rate Charge/Discharge Tests on batteries used for EV application (Dynamic Stress Test) and High Rate Discharge test
4.0 Density Meter : 1 nos Anton Par make
• Range - 0 - 1.999 g/cmc
• Resolution 0.0001 gm/cmc
• Uncertainty :- + 0.001 gm/cmc
• Temperature 0 - 40 degree
• Resolution 0.1 degree
• battery operated
2. Testing Conducted:
Lead Acid Storage Batteries
3. Test Standard Followed :
ASRTU (AS:62:68:DEC:2004)
ASRTU (AS:311:69:DEC:2004)
IS:7372:1995.
IS:14257:1995.
DIN:5301:1995-97.
Any test requested by customer.